Dynamic Temperature Control Systems

A fully closed piping design, high efficiency plate heat exchanger used to reduce the demand for the thermal fluid utilization while providing the system to achieve the rapid ups and downs in temperature The whole system is a closed liquid circulation system with the expansion of container, expansion of the container and the liquid circulation is adiabatic, and do not participate in liquid circulation, only mechanical

  • Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is limited to 60°C).
  • No volatilization of the heat conducting medium at high temperature.
  • No need to change the heat conducting medium.
    Continuous control of the temperature of the below range can be done without rising the pressure: -80°C~190°C, -70°C 220°C, -88°C 170°C, -55°C 250°C, -30°C 300°C.

Typical Applications

  • Reactor Systems Autoclaves
  • Pilot Systems
  • Mini Plant Systems
  • Scale up for Operational Development
  • Double wall reactors
  • Advanced-Flow Reactors
  • Distillation Systems
  • Material Testing
  • Combinational Chemistry
  • Semiconductor Industry
  • Vacuum Chambers

Advantages & Functions

  • Working temperatures from -100°C to +350°C
  • Previously unachievable performance
  • Intelligent temperature control
  • Maximum process stability and reproducibility
  • Adop plate heat exchager,Pipeline heating,the fastest heating and cooling rates.
  • High cooling power from 0.5 to 400kW
  • Large temperature range without fluid change
  • Incredibly compact
  • 7-inch,10-inch color TFT touch screen display
  • Comprehensive warning and safety functions
  • Rapid cooling down from high temperature (from 300 °C)
  • Closed system,extend thermal fluid lifetime
  • Use magnetic drive pump,solve the circulation pump leakage
Machine Outlet Temp range: -25 DegC to 200 DegC
Model TCU-225W TCU-235W TCU-255W TCU-275W TCU-2A10W
Control mode Feedback PID + special dynamic control calcula8on, PLC controller
Temp Control Process temp control and jacket temp control model
Program Editor 10 programs, each program can edit 42 steps
Communication MODBUS RTU Protocol, RS 485 Interface
Material temp feedback PT100 or 4-20 mA or communication
Material temp accuracy +/- 1 DegC
Heating power (kW) 2.5 3.5 5.5 7.5 10
Cooling Capacity kW at 200 C 2.5 3.5 5.5 7.5 10
100 C 2.5 3.5 5.5 7.5 10
20 C 2.5 3.5 5.5 7.5 10
-5 C 2 3 4.5 6.6 8
-20 C 1 1.8 2.8 3.8 4.6
Pump circulation 20 L/min
2 bar 
35 L/min
2 bar 
35 L/min
2 bar 
50 L/min
2 bar
50 L/min
2 bar
Compressor Emerson copeland / Danfoss scroll compressor
Expansion valve Emerson thermal expansion valve / Danfoss thermal expansion valve
Evaporator DANFOSS / KAORI Plate heat exchanger
Operation Panel 7-inch touch screen, show temp curve / Excel data output
Safety Protection Self diagnosis function, freezer overload protection, high pressure switch, overload relay, thermal protec8on, device, high temp protec8on, and temp fault protection
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temp and no water vapour at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature
Refrigerant R-404A/R507C, optional: R448A
Connection size G1/2 G3/3 G3/4 G1 G1
Water cooled type W (@ 20 DegC) 600 L/H 1.5- 4 bar G3/8 800 L/H 1.5- 4 bar G1/2 1000 L/H 1.5- 4 bar G3/4 1200 L/H 1.5- 4 bar G3/4 1600 L/H 1.5- 4 bar G3/4
Dimensions(mm) W*D*H 450*650*1200 500*850* 1300 500*850* 1300 550*1000 *1750 700*1000*1750
Weight (kg) 115 165 185 230 280
Power MAX 380V 50Hz AC 220V 50Hz
4 kW max
6 kW 8 kW 11 kW 14 kW
Machine Outlet Temp range: -45 DegC to 250 DegC
Model TCU-525W TCU-535W TCU-555W TCU-575W TCU-5A10W
Control mode Feedback PID + special dynamic control calcula8on, PLC controller
Temp Control Process temp control and jacket temp control model
Program Editor 10 programs, each program can edit 42 steps
Communication MODBUS RTU Protocol, RS 485 Interface
Material temp feedback PT100 or 4-20 mA or communica8on
Material temp accuracy +/- 1 DegC
Heating power (kW) 2.5 3.5 5.5 7.5 10
Cooling Capacity kW at 250 C 2.5 3.5 5.5 7.5 10
20 C 2.5 3.5 5.5 7.5 10
0 C 2.5 3.5 5.5 7.5 10
-20 C 0.85 1.5 2.9 4.2 6
-40 C 0.25 0.45 0.9 1.5 2
Pump circulation 20 L/min
2 bar 
35 L/min
2 bar 
35 L/min
2 bar 
50 L/min
2 bar
60 L/min
2.5 bar
Compressor Emerson copeland/ Danfoss scroll compressor
Expansion valve Emerson thermal expansion valve/ Danfoss thermal expansion valve
Evaporator DANFOSS / KAORI Plate heat exchanger
Operation Panel 7-inch touch screen, show temp curve/ Excel data output
Safety Protection Self diagnosis function, freezer overload protection, high pressure switch, overload relay, thermal protec8on, device, high temp protection, and temp fault protection
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temp and no water vapour at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature
Refrigerant R-404A/R507C, optional: R448A
Connection size G3/4 G3/4 G3/4 G3/4 G1
Water cooled type W (@ 20 DegC) 600 L/H 1.5- 4 bar G3/8 800 L/H 1.5- 4 bar G1/2 1500 L/H 1.5- 4 bar G3/4 1800 L/H 1.5- 4 bar G3/4 2600 L/H 1.5- 4 bar G1
Dimensions(mm) W*D*H 500*850*1300 550*1000* 1750 550*1000* 1750 550*1000 *1750 700*1000*1750
Weight (kg) 130 180 195 260 320
Power MAX 380V 50Hz AC 220V 50Hz
4.5 kW max
6.5 KW 9 KW 11.5 KW 16 KW
Machine Outlet Temp range: -60 DegC to 250 DegC
Model TCU-625W TCU-635W TCU-655W TCU-675W TCU-6A10W
Control mode Feedback PID + special dynamic control calculation, PLC controller
Temp Control Process temp control and jacket temp control model
Program Editor 10 programs, each program can edit 42 steps
Communication MODBUS RTU Protocol, RS 485 Interface
Material temp feedback PT100 or 4-20 mA or communica8on
Material temp accuracy +/- 1 DegC
Heating power (kW) 2.5 3.5 6 7.5 10
Cooling Capacity kW at 250 C 2.5 3.5 5.5 7.5 10
20 C 2.5 3.5 5.5 7.5 10
-20 C 2 3 4.8 6 8.2
-40 C 0.95 1.45 2.3 3.1 4.8
-55 C 0.25 0.5 0.75 0.9 1.5
Pump circulation 20 L/min
2 bar 
35 L/min
2 bar 
50 L/min
2 bar 
50 L/min
2 bar
60 L/min
2.5 bar
Compressor Emerson copeland/ Danfoss scroll compressor
Expansion valve Emerson thermal expansion valve/ Danfoss thermal expansion valve
Evaporator DANFOSS / KAORI Plate heat exchanger
Operation Panel 7-inch touch screen, show temp curve/ Excel data output
Safety Protection Self diagnosis function, freezer overload protection, high pressure switch, overload relay, thermal protec8on, device, high temp protection, and temp fault protection
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temp and no water vapour at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature
Refrigerant R-404A/R507C, optional: R448A
Connection size G1/2 G3/4 G3/4 G1 G1
Water cooled type W (@ 20 DegC) 900 L/H 1.5- 4 bar G1/2 1200 L/H 1.5- 4 bar G3/4 1800 L/H 1.5- 4 bar G3/4 2100 L/H 1.5- 4 bar G3/4 3000 L/H 1.5- 4 bar G1
Dimensions(mm) W*D*H 450*650*1200 550*1000* 1750 550*1000* 1750 550*1000 *1750 700*1000*1750
Weight (kg) 205 225 300 340 380
Power MAX 380V 50Hz 5 KW 7.5 kW 10 kW 14 kW 18 kW
Machine Outlet Temp range: -80 DegC to 250 DegC
Model TCU-825W TCU-835W TCU-855W TCU-875W TCU-8A10W
Control mode Feedback PID + special dynamic control calculation, PLC controller
Temp Control Process temp control and jacket temp control model
Program Editor 10 programs, each program can edit 42 steps
Communication MODBUS RTU Protocol, RS 485 Interface
Material temp feedback PT100 or 4-20 mA or communica8on
Material temp accuracy +/- 1 DegC
Heating power (kW) 2.5 3.5 5.5 7.5 10
Cooling Capacity kW at 250 C 2.5 3.5 5.5 7.5 10
100 C 2.5 3.5 5.5 7.5 10
-20 C 2 3 4.8 6 8.2
-40 C 1.8 2.6 3.3 5.8 6.4
-60 C 1 1.4 1.6 3 3.5
-75 C 0.3 0.42 0.7 1.3 1.5
Pump circulation 20 L/min
2 bar 
35 L/min
2 bar 
35 L/min
2 bar 
50 L/min
2 bar
60 L/min
2.5 bar
Compressor Emerson copeland/ Danfoss scroll compressor
Expansion valve Emerson thermal expansion valve/ Danfoss thermal expansion valve
Evaporator DANFOSS / KAORI Plate heat exchanger
Operation Panel 7-inch touch screen, show temp curve/ Excel data output
Safety Protection Self diagnosis function, freezer overload protection, high pressure switch, overload relay, thermal protec8on, device, high temp protection, and temp fault protection
Closed circulation system The whole system is full closed circulation, there is no oil mist at high temp and no water vapour at low temp, pressure do not rise up when system is running. The system will supply oil automatically at low temperature
Refrigerant R-404A/R507C, optional: R448A
Connection size G1/2 G3/4 G3/4 G1 G1
Water cooled type W (@ 20 DegC) 900 L/H 1.5- 4 bar G1/2 1200 L/H 1.5- 4 bar G3/4 1800 L/H 1.5- 4 bar G3/4 2300 L/H 1.5- 4 bar G3/4 3200 L/H 1.5- 4 bar G1
Dimensions(mm) W*D*H 550*1000* 1750 550*1000* 1750 550*1000* 1750 700*1000 *1750 700*1000*1750
Weight (kg) 240 285 345 500 600
Power MAX 380V 50Hz 6.5 KW 10 kW 13 kW 19 kW 25 kW
Copyright © 2016 jagdamba-enterprise.in. All rights reserved.